22 research outputs found

    Evolution of the use of corticosteroids for the treatment of hospitalised COVID-19 patients in Spain between March and November 2020: SEMI-COVID national registry

    Get PDF
    Objectives: Since the results of the RECOVERY trial, WHO recommendations about the use of corticosteroids (CTs) in COVID-19 have changed. The aim of the study is to analyse the evolutive use of CTs in Spain during the pandemic to assess the potential influence of new recommendations. Material and methods: A retrospective, descriptive, and observational study was conducted on adults hospitalised due to COVID-19 in Spain who were included in the SEMI-COVID- 19 Registry from March to November 2020. Results: CTs were used in 6053 (36.21%) of the included patients. The patients were older (mean (SD)) (69.6 (14.6) vs. 66.0 (16.8) years; p < 0.001), with hypertension (57.0% vs. 47.7%; p < 0.001), obesity (26.4% vs. 19.3%; p < 0.0001), and multimorbidity prevalence (20.6% vs. 16.1%; p < 0.001). These patients had higher values (mean (95% CI)) of C-reactive protein (CRP) (86 (32.7-160) vs. 49.3 (16-109) mg/dL; p < 0.001), ferritin (791 (393-1534) vs. 470 (236- 996) µg/dL; p < 0.001), D dimer (750 (430-1400) vs. 617 (345-1180) µg/dL; p < 0.001), and lower Sp02/Fi02 (266 (91.1) vs. 301 (101); p < 0.001). Since June 2020, there was an increment in the use of CTs (March vs. September; p < 0.001). Overall, 20% did not receive steroids, and 40% received less than 200 mg accumulated prednisone equivalent dose (APED). Severe patients are treated with higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%. Conclusions: Patients with greater comorbidity, severity, and inflammatory markers were those treated with CTs. In severe patients, there is a trend towards the use of higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%

    Seguimiento de las guías españolas para el manejo del asma por el médico de atención primaria: un estudio observacional ambispectivo

    Get PDF
    Objetivo Evaluar el grado de seguimiento de las recomendaciones de las versiones de la Guía española para el manejo del asma (GEMA 2009 y 2015) y su repercusión en el control de la enfermedad. Material y métodos Estudio observacional y ambispectivo realizado entre septiembre del 2015 y abril del 2016, en el que participaron 314 médicos de atención primaria y 2.864 pacientes. Resultados Utilizando datos retrospectivos, 81 de los 314 médicos (25, 8% [IC del 95%, 21, 3 a 30, 9]) comunicaron seguir las recomendaciones de la GEMA 2009. Al inicio del estudio, 88 de los 314 médicos (28, 0% [IC del 95%, 23, 4 a 33, 2]) seguían las recomendaciones de la GEMA 2015. El tener un asma mal controlada (OR 0, 19, IC del 95%, 0, 13 a 0, 28) y presentar un asma persistente grave al inicio del estudio (OR 0, 20, IC del 95%, 0, 12 a 0, 34) se asociaron negativamente con tener un asma bien controlada al final del seguimiento. Por el contrario, el seguimiento de las recomendaciones de la GEMA 2015 se asoció de manera positiva con una mayor posibilidad de que el paciente tuviera un asma bien controlada al final del periodo de seguimiento (OR 1, 70, IC del 95%, 1, 40 a 2, 06). Conclusiones El escaso seguimiento de las guías clínicas para el manejo del asma constituye un problema común entre los médicos de atención primaria. Un seguimiento de estas guías se asocia con un control mejor del asma. Existe la necesidad de actuaciones que puedan mejorar el seguimiento por parte de los médicos de atención primaria de las guías para el manejo del asma. Objective: To assess the degree of compliance with the recommendations of the 2009 and 2015 versions of the Spanish guidelines for managing asthma (Guía Española para el Manejo del Asma [GEMA]) and the effect of this compliance on controlling the disease. Material and methods: We conducted an observational ambispective study between September 2015 and April 2016 in which 314 primary care physicians and 2864 patients participated. Results: Using retrospective data, we found that 81 of the 314 physicians (25.8%; 95% CI 21.3–30.9) stated that they complied with the GEMA2009 recommendations. At the start of the study, 88 of the 314 physicians (28.0%; 95% CI 23.4–33.2) complied with the GEMA2015 recommendations. Poorly controlled asthma (OR, 0.19; 95% CI 0.13–0.28) and persistent severe asthma at the start of the study (OR, 0.20; 95% CI 0.12–0.34) were negatively associated with having well-controlled asthma by the end of the follow-up. In contrast, compliance with the GEMA2015 recommendations was positively associated with a greater likelihood that the patient would have well-controlled asthma by the end of the follow-up (OR, 1.70; 95% CI 1.40–2.06). Conclusions: Low compliance with the clinical guidelines for managing asthma is a common problem among primary care physicians. Compliance with these guidelines is associated with better asthma control. Actions need to be taken to improve primary care physician compliance with the asthma management guidelines

    Versatile wide angle diffraction setup for simultaneous wide and small angle x-ray scattering measurements with synchrotron radiation

    Get PDF
    5 pages, 10 figures.Here we present a novel, simple, and versatile experimental setup aimed to perform wide angle x-ray scattering (WAXS) measurements alone or in simultaneous combination with small angle x-ray scattering measurements. The design of the WAXS goniometer allows one to obtain high resolution diffraction patterns in a broad angular range. The setup can incorporate a hot stage in order to evaluate temperature resolved experiments. The performance of the equipment has been verified in the BM16 beam line of the European Synchrotron Radiation Facility with different well known samples such as alumina, isotropic film of high density polyethylene (HDPE), and oriented HPDE fiber.The authors are indebted to the Spanish Ministry of Science and Education (Grant No. FPA2001-2139) and to the EU, Marie-Curie reintegration grant (MERG-CT-2004-511908)for the financial support of this project.Peer reviewe

    Abnormalities on 1q and 7q are associated with poor outcome in sporadic Burkitt's lymphoma. A cytogenetic and comparative genomic hybridization study

    No full text
    Comparative genomic hybridization (CGH) studies have demonstrated a high incidence of chromosomal imbalances in non-Hodgkin's lymphoma. However, the information on the genomic imbalances in Burkitt's Lymphoma (BL) is scanty. Conventional cytogenetics was performed in 34 cases, and long-distance PCR for t(8;14) was performed in 18 cases. A total of 170 changes were present with a median of four changes per case (range 1-22). Gains of chromosomal material (143) were more frequent than amplifications (5) or losses (22). The most frequent aberrations were gains on chromosomes 12q (26%), Xq (22%), 22q (20%), 20q (17%) and 9q (15%). Losses predominantly involved chromosomes 13q (17%) and 4q (9%). High-level amplifications were present in the regions 1q23-31 (three cases), 6p12-p25 and 8p22-p23. Upon comparing BL vs Burkitt's cell leukemia (BCL), the latter had more changes (mean 4.3 ± 2.2) than BL (mean 2.7 ± 3.2). In addition, BCL cases showed more frequently gains on 8q, 9q, 14q, 20q, and 20q, 9q, 8q and 14q, as well as losses on 13q and 4q. Concerning outcome, the presence of abnormalities on 1q (ascertained either by cytogenetics or by CGH), and imbalances on 7q (P = 0.01) were associated with a short survival.This work was partially supported by Grants of Spanish FIS (01/3153; 02/1358 & 02/1041).Peer Reviewe

    Thin-film electrochemical sensor for diphenylamine detection using molecularly imprinted polymers

    No full text
    This work reports on the development of a new voltammetric sensor for diphenylamine based on the use of a miniaturized gold electrode modified with a molecularly imprinted polymer recognition element. Molecularly imprinted particles were synthesized ex situ and further entrapped into a poly(3,4-ethylenedioxythiophene) polymer membrane, which was electropolymerized on the surface of the gold electrode. The thickness of the polymer layer was optimized in order to get an adequate diffusion of the target analyte and in turn to achieve an adequate charge transfer at the electrode surface. The resulting modified electrodes showed a selective response to diphenylamine and a high sensitivity compared with the bare gold electrode and the electrode modified with poly(3,4-ethylenedioxythiophene) and non-imprinted polymer particles. The sensor showed a linear range from 4.95 to 115. μM diphenylamine, a limit of detection of 3.9. μM and a good selectivity in the presence of other structurally related molecules. This sensor was successfully applied to the quantification of diphenylamine in spiked apple juice samples

    Prognosis of venous thromboembolism in orthopaedic surgery or trauma patients and use of thromboprophylaxis.

    No full text
    BACKGROUND: There is scarce evidence about the prognosis of venous thromboembolism in patients undergoing orthopedic surgery and in patients suffering non-surgical trauma. METHODS: We used the RIETE database (Registro Informatizado de pacientes con Enfermedad Trombo Embólica) to compare the prognosis of venous thromboembolism and the use of thromboprophylaxis in patients undergoing different orthopedic procedures and in trauma patients not requiring surgery. RESULTS: From March 2001 to March 2015, a total of 61,789 patients were enrolled in RIETE database. Of these, 943 (1.52%) developed venous thromboembolism after elective arthroplasty, 445 (0.72%) after hip fracture, 1,045 (1.69%) after non-major orthopedic surgery and 2,136 (3.46%) after non-surgical trauma. Overall, 2,283 patients (50%) initially presented with pulmonary embolism. Within the first 90 days of therapy, 30 patients (0.66%; 95% CI 0.45-0.93) died from pulmonary embolism. The rate of fatal pulmonary embolism was significantly higher after hip fracture surgery (n = 9 [2.02%]) than after elective arthroplasty (n = 5 [0.53%]), non-major orthopedic surgery (n = 5 [0.48%]) or non surgical trauma (n = 11 [0.48%]). Thromboprophylaxis was more commonly used for hip fracture (93%) or elective arthroplasty (94%) than for non-major orthopedic surgery (71%) or non-surgical trauma (32%). Major bleeding was significantly higher after hip fracture surgery (4%) than that observed after elective arthroplasty (1.6%), non-major orthopedic surgery (1.5%) or non-surgical trauma (1.4%). CONCLUSIONS: Thromboprophylaxis was less frequently used in lower risk procedures despite the absolute number of fatal pulmonary embolism after non-major orthopedic surgery or non-surgical trauma, exceeded that observed after high risk procedures.pre-print441 K

    Pronóstico de la enfermedad tromboembólica venosa en cirugía ortopédica o pacientes traumatológicos y uso de tromboprofilaxis.

    No full text
    There is scarce evidence about the prognosis of venous thromboembolism in patients undergoing orthopedic surgery and in patients suffering non-surgical trauma. We used the RIETE database (Registro Informatizado de pacientes con Enfermedad Trombo Embólica) to compare the prognosis of venous thromboembolism and the use of thromboprophylaxis in patients undergoing different orthopedic procedures and in trauma patients not requiring surgery. From March 2001 to March 2015, a total of 61,789 patients were enrolled in RIETE database. Of these, 943 (1.52%) developed venous thromboembolism after elective arthroplasty, 445 (0.72%) after hip fracture, 1,045 (1.69%) after non-major orthopedic surgery and 2,136 (3.46%) after non-surgical trauma. Overall, 2,283 patients (50%) initially presented with pulmonary embolism. Within the first 90 days of therapy, 30 patients (0.66%; 95% CI 0.45-0.93) died from pulmonary embolism. The rate of fatal pulmonary embolism was significantly higher after hip fracture surgery (n = 9 [2.02%]) than after elective arthroplasty (n = 5 [0.53%]), non-major orthopedic surgery (n = 5 [0.48%]) or non surgical trauma (n = 11 [0.48%]). Thromboprophylaxis was more commonly used for hip fracture (93%) or elective arthroplasty (94%) than for non-major orthopedic surgery (71%) or non-surgical trauma (32%). Major bleeding was significantly higher after hip fracture surgery (4%) than that observed after elective arthroplasty (1.6%), non-major orthopedic surgery (1.5%) or non-surgical trauma (1.4%). Thromboprophylaxis was less frequently used in lower risk procedures despite the absolute number of fatal pulmonary embolism after non-major orthopedic surgery or non-surgical trauma, exceeded that observed after high risk procedures

    Detection of SARS-CoV-2 Virus by Triplex Enhanced Nucleic Acid Detection Assay (TENADA)

    Get PDF
    SARS-CoV-2, a positive-strand RNA virus has caused devastating effects. The standard method for COVID diagnosis is based on polymerase chain reaction (PCR). The method needs expensive reagents and equipment and well-trained personnel and takes a few hours to be completed. The search for faster solutions has led to the development of immunological assays based on antibodies that recognize the viral proteins that are faster and do not require any special equipment. Here, we explore an innovative analytical approach based on the sandwich oligonucleotide hybridization which can be adapted to several biosensing devices including thermal lateral flow and electrochemical devices, as well as fluorescent microarrays. Polypurine reverse-Hoogsteen hairpins (PPRHs) oligonucleotides that form high-affinity triplexes with the polypyrimidine target sequences are used for the efficient capture of the viral genome. Then, a second labeled oligonucleotide is used to detect the formation of a trimolecular complex in a similar way to antigen tests. The reached limit of detection is around 0.01 nM (a few femtomoles) without the use of any amplification steps. The triplex enhanced nucleic acid detection assay (TENADA) can be readily adapted for the detection of any pathogen requiring only the knowledge of the pathogen genome sequence
    corecore